EYE ON FIBER
Volume 1, Issue 1
August 2002
Part 1: The Six Subtleties of Accurate Singlemode Testing
I have observed some problems that occur when installers perform insertion loss testing of singlemode jumpers (aka, patch cords) and links. While investigating these problems, I identified six subtle, and critical steps which the tester must take. If the tester takes these steps, he will obtain the most accurate and the most repeatable singlemode loss measurements possible.
These six steps are:
qualify the reference leads
use singlemode barrels, not singlemode / multimode barrels
determine the directional effect of the barrels and use the barrels in their optimum directions
use a laser diode light source
clean, clean and re-clean
make multiple measurements for ST-compatible connectors
Step 1: Qualify the Reference Leads Regardless of whether you test
according to Method A or Method B of TIA/EIA-526-14, you must have low loss
connectors on your reference leads.
Otherwise, all your test results will be higher than reality and you
risk rejecting jumpers or links which are acceptable. You verify low loss connectors on your reference leads by
qualifying those leads.
This qualification is simple, but a bit time consuming. See Figures 1 and 2 for the procedure. You will need two test leads, which we will label A and B. To qualify these two test leads, you will need to test each of these four connectors on the two reference leads against the other three. This testing must be done in both directions, since connectors do exhibit different losses on opposite directions (the directional effect). If all of the tests, x1...x8, produce values which are higher values than -0.50 dB (e.g., -0.35 dB), you can use these two leads as reference leads. The fact that you are qualifying two leads against each other means that reference leads are matched pairs. If one lead is damaged, you must requalify a potential new reference lead against the remaining good reference lead.
This qualification value of 0.50 dB is an arbitrary number, based on the field experiences of my associates and myself. If you use a qualification value worse than -0.50 dB, like -0.70 dB, you are likely to reject jumpers and links which are good, an undesirable decision.
If you use a qualification value better than -0.50 dB, like -0.30 dB, you will find yourself rejecting potentially good reference leads which will provide accurate loss measurements.

Figure 1: Qualification of Lead B
Against Lead A

Figure 2: Qualification of Lead A
Against Lead B
Recently, we recertified four singlemode reference leads from two
of our test kits. The results are
in Tables 1 and 2 (in dB). Since
all of the values in Table 1 were lower than 0.50 dB, these two reference leads
can be used. Since all of the
values in Table 2 were not lower than 0.50 dB, these two reference leads can
not be used.
Table 1: Qualification Results for
Reference Leads 4 and 19
|
x1 |
x2 |
x3 |
x4 |
x5 |
x6 |
x7 |
x8 |
|
-0.42 |
-0.04 |
-0.01 |
-0.13 |
-0.21 |
-0.10 |
-0.03 |
-0.34 |
Table 2: Qualification Results for
Reference Leads 11 and 9
|
x1 |
x2 |
x3 |
x4 |
x5 |
x6 |
x7 |
x8 |
|
-0.59 |
-0.17 |
-0.67 |
-0.38 |
-0.48 |
-0.28 |
-0.23 |
-0.66 |
Step 2: Use Singlemode Barrels Three types of barrels are available: multimode, singlemode/multimode, and singlemode. Obviously, you do not want to test singlemode cables with multimode barrels. You might think that singlemode / multimode barrels will work. However, preliminary test results suggest that singlemode barrels will provide lower insertion loss values and better repeatability. All our current and future singlemode testing will be done with barrels designated singlemode.
Step 3: Determine Barrel Directional Effects While it may not be obvious, singlemode barrels do not provide the same loss when the barrel is reversed. There is a small, but significant directional effect. This directional effect becomes significant because it is about the same value of the low loss of singlemode connectors available at this time.
When tested by the procedure in Figure 3, which is called the single end loss test, the singlemode barrels Pearson Technologies uses exhibited the directional effects in Table 4. This table indicates an average directional effect of almost 0.10 dB. While this average may seem small, insertion loss testing by Method A or B of TIA/EIA-526-14 requires two barrels. If both barrels are used in the direction providing the higher loss, then the test results could be biased 0.20 dB higher than reality. For relatively long outdoor links, this bias will be insignificant. However, for short distance indoor links, this bias could cause rejection of properly installed links.

Figure 3:
Qualification of Lead A Against Lead B
Table 4: Directional Effects of
ST-Compatible Singlemode Barrels
|
Barrel # |
Loss, D1, in dB |
Loss, D2, in dB |
Directional
Effect, in dB |
|
6 |
-0.15 |
-0.13 |
0.02 |
|
7 |
-0.16 |
-0.23 |
0.07 |
|
8 |
-0.08 |
-0.15 |
0.07 |
|
9 |
-0.20 |
-0.05 |
0.15 |
|
10 |
-0.09 |
-0.20 |
0.11 |
|
11 |
-0.06 |
-0.20 |
0.14 |
|
12 |
-0.03 |
-0.13 |
0.10 |
Step 4: Use a Laser Source The goal of insertion loss testing is the simulation of operating conditions. The more closely the testing conditions simulate the operating conditions, the closer the insertion loss values will be to the loss experienced by the transmitter-receiver pair. Such simulation requires use a laser diode light source. While the 1300 nm multimode testing source may seem similar enough to the 1310 nm singlemode source to use the former to test the latter, the similarity is not close enough. Use of a multimode source to test singlemode links can produce loss values which are higher than reality. While such a situation makes for conservative testing conditions, it also can result in rejecting good links due to high loss. We investigated this effect in order to quantify the difference.
We tested singlemode samples by Method A, the two lead method, of TIA/EIA-526-14. We tested the samples with a singlemode, 1310 nm laser source and with a multimode, 1300 nm LED source with the same reference leads. The results are in Table 5. The bold values highlight the general trend of higher loss values from the multimode source than from the singlemode source. Note that the positive loss measurements in Table 5 are an intrinsic problem of Method A and do not represent measurement errors.
Table 5: 1300 nm
vs. 1310 nm Loss Values
|
|
Forward loss |
Forward loss |
Difference, |
Reverse loss |
Reverse loss |
Difference, |
|
Sample |
1300 |
1310 |
dB |
1300 |
1310 |
dB |
|
4 |
-.06 |
-0.18 |
+0.12 |
-0.07 |
-0.19 |
+0.12 |
|
7 |
-0.32 |
-0.03 |
-0.29 |
-0.26 |
+0.04 |
-0.22 |
|
8 |
-0.28 |
-0.05 |
-0.23 |
-0.05 |
-0.00 |
-0.05 |
|
9 |
-0.40 |
-0.40 |
0.00 |
-0.56 |
-0.18 |
-0.38 |
|
10 |
+0.20 |
+0.19 |
+0.01 |
0.00 |
+0.10 |
-0.10 |
|
11 |
-0.09 |
+0.43 |
-0.52 |
-0.19 |
0 |
-0.19 |
|
12 |
-0.06 |
-0.01 |
-0.05 |
-0.13 |
+0.06 |
-0.19 |
Step 5: Clean, Clean and Reclean While cleaning is important for low loss multimode connectors, it is critical for singlemode connectors. If not properly cleaned, acceptable low loss, low reflectance connectors can be rejected. Table 6 has examples of the reduction or improvement in loss after cleaning.
Table 6: Insertion Loss Improvement
After Cleaning
|
Loss before
cleaning |
Loss after
cleaning |
Improvement,
dB |
|
-0.35 |
-0.07 |
0.28 |
|
-0.40 |
-0.13 |
0.27 |
|
-0.13 |
+0.08 |
0.21 |
|
-0.17 |
-0.01 |
0.16 |
Cleaning can be done with acetone or a connector cleaner, such as Electro-Wash Px from Chemtronics (www. Chemtronics.com). We use both, since our informal testing reveals no significant difference between Electro-Wash and acetone.
Many use 98% isopropyl alcohol for cleaning connectors. There is not question that isopropyl is acceptable for cleaning fibers prior to connector installation or to splicing. We have found that this alcohol can be acceptable for cleaning multimode connectors if the connectors are wiped with a dry lens grade tissue immediately after being wiped with a tissue moistened with isopropyl.
However, isopropyl alcohol is consistently unacceptable for
cleaning singlemode connectors. It
is impossible to achieve both consistent low loss and low reflectance with
alcohol as a connector cleaning liquid.
Step 6: Make Multiple Measurements We have observed that singlemode ST-compatible connectors do not always seat fully or immediately. Usually, this behavior is not troublesome for multimode connectors. However, this behavior forces a change in the testing procedure and in an increase in the testing time of singlemode connectors. We present typical results in Table 7. The average for the range values in Table 7 is 0.07 dB.
We have not tested singlemode SC connectors to determine whether they behave in a manner similar to that of the singlemode ST-compatible connectors.
Table 7: Variation of Insertion
Loss Values During Range/Repeatability Testing
|
Sample |
Direction |
Meas. 1 |
Meas. 2 |
Meas. 3 |
Range, dB |
|
6 |
forward |
0.20 |
0.20 |
0.23 |
0.03 |
|
6 |
reverse |
0.23 |
0.17 |
0.08 |
0.15 |
|
7 |
forward |
0.12 |
0.16 |
0.19 |
0.07 |
|
7 |
reverse |
0.23 |
0.24 |
0.22 |
0.02 |
|
8 |
forward |
0.03 |
0.13 |
0.07 |
0.10 |
|
8 |
reverse |
0.14 |
0.12 |
0.20 |
0.08 |
|
9 |
forward |
0.18 |
0.18 |
0.23 |
0.05 |
|
9 |
reverse |
0.09 |
0.00 |
0.07 |